Liquiphant T FTL20 Sensor length:
35 mm / 1.4" Temperature:
-40...150 °C / -40...302 °F Pressure:
-1...40 bar / -14.5...580 psi Process connection:
½", ¾", 1" Output:
AC, DC, ASi
Liquiphant T FTL20H Sensor length:
35 mm / 1.4" Temperature:
-40...150 °C / -40...302 °F Pressure:
-1...40 bar / -14.5...580 psi Process connection:
½", ¾", 1", Triclamp, diary, flush-mounted versions Output:
AC, DC, ASi
Liquiphant T FTL260 Temperature:
-40...+150°C (-40...+302°F) Process connections:
1" NPT to ANSI B 1.20.1 316 SS
G1 A to DIN ISO 228/1, 316 SS
R1 to DIN 2999 Part 1, 316 SS Power supply:
AC, 19...253V, 50/60Hz
Liquiphant M
Liquiphant M FTL50 Sensor length:
65 mm / 2.6" Temperature:
-50...150 °C / -58...302 °F Pressure:
-1...63 bar / -14.5...914 psi Process connection:
¾", 1", flanges Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS
Liquiphant M FTL50H Sensor length:
65 mm / 2.6" Temperature:
-50...150 °C / -58...302 °F Pressure:
-1...63 bar / -14.5...914 psi Process connection:
¾", 1", flanges Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS
Liquiphant M FTL51 Sensor length:
148...6000 mm / 5.5 ...118" Temperature:
-50...150 °C / -58...302 °F Pressure:
-1...63 bar / -14.5...914 psi Process connection:
¾", 1", flanges Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS
Liquiphant M TL51C Sensor length:
148...3000 mm / 5.5...118" Temperature:
-50...150 °C / -58...302 °F Pressure:
-1...40 bar / -14.5...580 psi Process connection:
Flanges Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS
Liquiphant M FTL51H Sensor length:
148...6000 mm / 5.5...118" Temperature:
-50...150 °C / -58...302 °F Pressure:
-1...63 bar / -14.5...914 psi Process connection:
¾", 1", flanges Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS
Liquiphant S
Liquiphant S FTL70 Sensor length:
65 mm /2.4" Temperature:
-60...280 °C / -76...536 °F Pressure:
-1...100 bar / -14.5...1450 psi Process connection:
¾", 1", flanges Output:
AC/DC, 8/16 mA, NAMUR, PFM PROFIBUS
Liquiphant S FTL71 Sensor length:
148...6000 mm / 5.8...236" Temperature:
-60...280 °C / -76...536 °F Pressure:
-1...100 bar / -14.5...1450 psi Process connection:
¾", 1", flanges Output:
AC/DC, 8/16 mA, NAMUR, PFM PROFIBUS
Liquiphant FailSafe
Liquiphant Failsafe FDL60 Sensor length:
130 mm / 5.1" Temperature:
-40...150 °C / -40...302 °F Pressure:
-1...40 bar / -14.5...580 psi Process connection:
1", flange Output:
PFM
Liquiphant Failsafe FDL61 Sensor length:
220...6000 mm / 8.7"...236" Temperature:
-40...150 °C / -40...302 °F Pressure:
-1...40 bar / -14.5...580 psi Process connection:
1", flange Output:
PFM
Liquiphant Failsafe FTL80 Sensor length:
65 mm / 2.6" Temperature:
–60 to 280 °C / –76 to 536 °FPressure:
-1...100 bar / -14.5...1450 psi Process connection:
¾", 1", flanges Output:
4-20 mA
Liquiphant Failsafe FTL81 Sensor length:
148...3000 mm / 5.5...118" Temperature:
–60 to 280 °C / –76 to 536 °F Pressure:
-1...100 bar / -14.5...1450 psi Process connection:
¾", 1", flanges Output:
4-20 mA
Liquiphant Failsafe FTL85 Sensor length:
148...3000 mm / 5.5...118" Temperature:
–50...150 °C / –58...302 °F Pressure:
-1...40 bar / -14.5...580 psi Process connection:
Flanges Output:
4-20 mA
Soliphant T
Soliphant T FTM20 Sensor length:
225 mm / 8.7" Temperature:
-40...150 °C Pressure:
-1...25 bar / -14.5...360 psi Density:
from 200 g/l, 12 lbs/ft³ Output:
DC, AC/DC relay
Soliphant T FTM21 Sensor length:
500, 1000, 2000 mm / 20, 40, 60" Temperature:
-40...150 °C / -40...302 °F Pressure:
-1...25 bar / -14.5...360 psi Density:
from 200 g/l, 12 lbs/ft³ Output:
DC, AC/DC relay
Soliphant M
Soliphant M FTM50 Sensor length:
145, 200 mm / 5.7, 8" Temperature:
-50...150 °C / -58...302 °F Pressure:
-1...25 bar / -14.5...360 psi Density:
from 8 g/l / 0.6 lbs/ft3 Output:
AC, DC, AC/DC relay, 8/16 mA, NAMUR, PFM
Soliphant M FTM51 Sensor length:
300...6000 mm / 11.8...236" Temperature:
-50...150 °C/ -58...302 °F Pressure:
-1...25 bar / -14.5...360 psi Density:
from 8 g/l / 0.6 lbs/ft³ Output:
AC, DC, AC/DC relay, 8/16 mA, NAMUR, PFM
Soliphant M FTM52 Sensor length:
750...20000 mm / 30...800" Temperature:
-40...80 °C / -40...176 °F Pressure:
-1...6 bar / -14.5...87 psi Density:
from 8 g/l / 0.6 lbs/ft³ Output:
AC, DC, AC/DC relay, 8/16 mA, NAMUR, PFM
Nivotester
Nivotester FTL325N Power supply:
AC, 85...253V, 50/60Hz
DC, 20..60V Ambient temperature:
Single installation -20°C...+140°C (-4°F...+60°F) Ingress protection:
NEMA 1 (IP20) Functional safety:
SIL 1 / SIL 2 Overspill protection:
WHG NAMUR interface
Nivotester FTL325P Power supply:
AC, 85...253V, 50/60Hz
DC, 20..60V Ambient temperature:
Single installation -20..+60°C
(-4...+140°F) Ingress protection:
NEMA 1 (IP20) Functional safety:
SIL 1 / SIL 2 / SIL 3 or AK 2 to 6
Nivotester FTL375P Housing:
Monorack / Racksyst Ambient temperature:
-20°C...+70°C Channels:
1 to 3 Overspill protection:
WHG Functional safety:
SIL 1 / SIL 2 / SIL 3 or AK 2...6
Nivotester Liquiphant FailSafe
Nivotester Liquiphant Failsafe FTL825 Power supply:
AC/DC, 85...253V
AC 20...30V, DC 20...60V Ambient temperature:
Single installation -20..+60°C
(-4...+140°F) Protection class:
IP20 Functional safety:
Up to SIL 3